Tycon Systems UPS-ST24-100-8-UBNT Installationsanleitung

Stöbern Sie online oder laden Sie Installationsanleitung nach Unterbrechungsfreie Stromversorgungen (USVs) Tycon Systems UPS-ST24-100-8-UBNT herunter. Tycon Systems UPS-ST24-50-8-UBNT uninterruptible power supply (UPS) Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 8
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
UPS-ST24 300W UBNT
UPSProBackup
Power System
Wireless Base Stations
Surveillance Cameras
Remote Gate Control
Electric Fence
Up to 192W loads
Congratulations! on your purchase of the UPSProoutdoor
backup power system. Please take a moment to review this Qwik
Install Guide before assembly or battery installation.
DANGER! Avoid Powerlines!
You Can Be Killed!
When following the instructions in this guide take extreme care
to avoid contact with overhead power lines, lights and power circuits.
Contact with power lines, lights or power circuits may be fatal. We rec-
ommend to install no closer than 20 feet to any power lines.
Safety: For your own protection, follow these safety rules.
Perform as many functions as possible on the ground
Do not attempt to install on a rainy, windy or snowy day or if
there is ice or snow accumulation at the install site or if the
site is wet.
Make sure there are no people, pets, etc. below when you are
working on a roof or ladder.
Recommended Tools: Phillips Screwdriver, 13mm and
10mm Open End Wrench, 8mm nut driver, Flat Blade Screwdriv-
Please help preserve the environment and return
used batteries to an authorized depot
Seitenansicht 0
1 2 3 4 5 6 7 8

Inhaltsverzeichnis

Seite 1 - Power System

UPS-ST24 300W UBNT UPSPro™ Backup Power System ▫ Wireless Base Stations ▫ Surveillance Cameras ▫ Remote Gate Control ▫ Electric Fence ▫ Up to

Seite 2 - Qwik Install

2 Qwik Install STEP 1: Add Grounding Wire Between Door and Enclosure: Remove plastic covers on cop-per studs on inside of door and inside of enclosur

Seite 3

3 STEP 4: If pole mounting the en-closure, assemble the pole mount kit to the back of the enclosure and mount the enclosure to a pole using the 6 ho

Seite 4

4 STEP 8: If batteries are installed on their side make sure to apply an insulator to the top of the battery termi-nal to prevent the battery termina

Seite 5

5 STEP 12: Switch off controller and connect AC to the controller. Be sure to follow local regulations for outdoor 120/240VAC connec-tions. STE

Seite 6 - SPECIFICATIONS

6 TECH CORNER Additional Information you may find useful 1. CONTROLLER: The controller turns off power to the load 21.5 and reconnects when the ba

Seite 7 - Limited Warranty

7 3. VENTING: The enclosure is vented thru the wire feedthrus and vari-ous hole plugs in the bottom of the enclosure. Don’t make these airtight with

Seite 8

8 8000027 Rev 1 UPS-ST24 300W UBNT UPSPro™ Qwik Install Guide